Kamis, 06 Februari 2014

Kyoritsu 3132A Analog Insulation Countinuity Tester

Kyoritsu 3132A Analog Insulation Countinuity Tester
Keterangan
• Dust and drip proof construction. ( designed to IEC 60529 IP54)
• Designed to meet IEC 61010-1 and IEC 61557 safety standard.
• 1mA rated test current at the minimum resistance.
• 200mA measuring current on continuity testing.
• Automatic discharge of circuit capacitance.
( Any charge stored in the circuit under test will be automatically discharged after testing.)
• Live circuit warning buzzer and neon lamp.
• Small and lightweight. Shock resistant new case material.
• AC voltmeter with linear, easy-to-read scale.
• Operates on AA, R6P× 6 dry batteries.

Insulation Resistance :
- Test Voltage : 250V/ 500V/ 1000V
- Measuring Ranges
( Mid-scale Value) : 100M© / 200M© / 400M©
( 1M© ) ( 2M© ) ( 4M© )
- Output Voltage
on open circuit : Rated test voltage+ 20% , -0%
- Nominal Current : 1mA DC min.
- Output Short
Circuit Current : 1~ 2mA DC
- Accuracy : 0.1~ 10M© / 0.2~ 20M© / 0.4~ 40M©
( Accuracy Guaranteed Ranges) ± 5% of indicated value
Continuity :
- Measuring Ranges
( Mid-scale Value) : 3© / 500©
( 1.5© ) / ( 20© )
- Output Voltage
on open circuit : 4.1V DC approx.
- Measuring Current : 210mA DC min.
- Accuracy : ± 1.5% of scale length
AC Voltage :
- AC Voltage : 0~ 600V AC
- Accuracy : ± 5% of scale length
General :
- Safety Standard : IEC 61010-1 CAT.III 600V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/ 2/ 4
- IP Rating : IEC 60529-IP54
- EMC Standard : IEC 61326-1
- Withstand Voltage : 3700V AC for 1 minute
- Power Source : R6P ( AA) ( 1.5V) × 6
- Dimensions : 106( L) × 160( W) × 72( D) mm
- Weight : 560g approx.
- Accessories : 7122 ( Test leads) Pouch for test leads
8923 ( F500mA/ 600V fuse) × 2
R6P ( AA) × 6
Shoulder Strap
Instruction Manual


Informasi Dan Pemesanan Hub. Hary Nugroho : 021.71601997 - 081806120636                               Fax : 021.7318012                    Email . alatsurveykita61@gmail.com 
 
 
 

Tidak ada komentar:

Posting Komentar