| General specifications | 
| Measuring functions | 
| 
 | 3-pole earth ground resistance, 2-pole ac resistance of a conductor,
Interference voltage |  | 
| Intrinsic error | 
| 
 | Refers to the reference temperature range and is guaranteed for one year |  | 
| Measuring rate |  | 
| Battery[1] | 
| 
 | One 9 volt alkaline (LR61) |  | 
| Battery condition | 
| 
 | LO-BAT is displayed if voltage drops below 6.5 V |  | 
| Voltages | 
| Between jacks H/C2 and E/C1: | 250 Veff maximum (effective voltage) |  | Between jacks S/P2 and E/C1: | 250 Veff maximum |  | 
| Climatic class | 
| 
 | VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) |  | 
| Temperature performance[2] | 
| Working: | -10 °C to +50 °C (+14 °F to +122 °F) |  | Operating: | 0 °C to +35 °C (+32 °F to +95 °F) |  | Storage: | -20 °C to +60 °C (+68 °F to +140 °F) |  | Reference: | +23 °C ± 2 °C (+73 °F ± 4 °F) |  | 
| Temperature coefficient | 
| 
 | ± 0.1 % of range per degree Kelvin |  | 
| Safety | 
| 
 | IEC/EN 61010-1, 600 V CAT II, pollution degree 2 |  | 
| Dimensions | 
| 
 | 113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster |  | 
| Weight | 
| 
 | 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 |  | 
| Note: | 
| 
 | [1]If the tester is not going to be used, or is being stored for a 
long period, remove the battery and store separately from the tester to 
avoid
damage from battery leakage. |  | 
| Note: | 
| 
 | [2]The four temperature ranges for the tester exists to satisfy 
European Standards requirements; the instrument can be used over the 
full
working temperature range by using the temperature coefficient to 
calculate accuracy at the ambient temperature of use. |  | 
| Electrical specifications | 
| Maximum deviations: | 
| E1 Influence factor | Position |  | E1 Deviation influence | 0 % |  | E2 Influence factor | Supply voltage |  | E2 Deviation influence | 0 % |  | E3 Influence factor | Temperature E3 |  | E3 Deviation influence | 2.3 % |  | E4 Influence factor | Serial interference voltage (20 V) |  | E4 Deviation influence | 0.6 % |  | E5 Influence factor | Probe- and auxiliary probe resistance |  | E5 Deviation influence | 10 % |  | 
| Test voltage |  | 
| Protection type |  | 
| Electromagnetic compatibility | 
| 
 | Emission: IEC/EN 61326 Class B |  | 
 | Immunity: IEC/EN 61326 Annex C |  | 
| RE resistance measurement | 
| Measuring method | Current-voltage measurement with improved cross-talk attenuation,
no compensation of measuring lead resistance, with probe (3-pole)
or without probe (2-pole), as per IEC/EN 61557-5 |  | Open circuit voltage | 23 to 24 V ac |  | Short circuit current | > 50 mA ac |  | Measuring frequency | 128 Hz |  | Maximum permissible
overload | 250 Veff |  | 
| Measuring time | 
| 
 | 8 seconds (average from when START is pressed) |  | 
| Limit input | 
| 
 | Tester retains set value even if instrument is turned off (assuming
battery power supply is sufficient) |  | 
| Automatic changeover of resolution | 
| RH | < 7 kΩ |  | Resolution | 0.01 Ω |  | RH | < 50 kΩ |  | Resolution | 0.1 Ω |  | RH | > 50 kΩ |  | Resolution | 1 Ω |  | 
| Interference voltage display dc + ac | 
| Vmax | 30 Veff |  | Common mode rejection | > 80 dB at 50 Hz and
60 Hz |  | Ri | 680 kΩ |  | Measuring uncertainty | < 10 % for pure ac
and dc signals |  | 
| Measuring
range | 
| 0.15 Ω to 20 Ω | 
| Resolution | 0.01 Ω |  | Display range | 0 to 19.99 Ω |  | 
| 200 Ω | 
| Resolution | 0.1 Ω |  | Display range | 20 to 199.9 Ω |  | 
| 2 kΩ | 
| Resolution | 1 Ω |  | Display range | 200 to 1999 Ω |  | 
| Intrinsic uncertainty | 
| 
 | ± (6 % of
measured value
+ 5D) |  | 
| Operating uncertainty IEC 61557[1] | 
| 
 | ± (18 % of measured value + 5D) |  | 
| Notes: | 
| 
 | [1] Covers all deviations caused by influence quantities E1-E5. If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes.
 Measured values are outside of the specified operating uncertainty.
 |  | 
Informasi Dan Pemesanan Hub. Hary Nugroho  : 021.71601997 - 081806120636                           Fax : 021.7318012  Email . alatsurveykita61@gmail.com
 
Tidak ada komentar: